Build directions

Sjöström Power Supply - For the Lynx amp by Jan Dupont

Click on the picture to get a larger view.

The heatsinks

There is nothing special to think about except for paying some attention to the heatsinks. They should be mounted approx. 1 mm above the pcb surface. Some heatsinks have the same potential as the groundplane but most of them don't. The heatsink is connected to cathode of all diodes.